FLAMEX® EN 50382-2 FFS
FLAMEX® EN 50382-2 FFS
Sheathed high temperature flexible shielded Power cables
Read moreFLAMEX SI EN 50382-2 1800V 120 FFS 120°C
Nexans ref. 10282209
- Packaging: Cut to length (m)
- Conductor cross-section: 120 mm²
- Rated Voltage Uo/U (Um): 1.8 / 3 kV
FLAMEX SI EN 50382-2 1800V 150 FFS 120°C
Nexans ref. 10282210
- Packaging: Cut to length (m)
- Conductor cross-section: 150 mm²
- Rated Voltage Uo/U (Um): 1.8 / 3 kV
FLAMEX SI EN 50382-2 1800V 95 FFS 120°C
Nexans ref. 10272931
- Packaging: Cut to length (m)
- Conductor cross-section: 95 mm²
- Rated Voltage Uo/U (Um): 1.8 / 3 kV
FLAMEX SI EN 50382-2 3600V 120 FFS 120°C
Nexans ref. 10260431
- Packaging: Cut to length (m)
- Conductor cross-section: 120 mm²
- Rated Voltage Uo/U (Um): 3.6/6 kV
FLAMEX SI EN 50382-2 3600V 150 FFS 120°C
Nexans ref. 10260432
- Packaging: Cut to length (m)
- Conductor cross-section: 150 mm²
- Rated Voltage Uo/U (Um): 3.6/6 kV
FLAMEX SI EN 50382-2 3600V 185 FFS 120°C
Nexans ref. 10260433
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Rated Voltage Uo/U (Um): 3.6/6 kV
FLAMEX SI EN 50382-2 3600V 50 FFS 120°C
Nexans ref. 10235715
- Packaging: Cut to length (m)
- Conductor cross-section: 50 mm²
- Rated Voltage Uo/U (Um): 3.6/6 kV
FLAMEX SI EN 50382-2 3600V 70 FFS 120°C
Nexans ref. 10260429
- Packaging: Cut to length (m)
- Conductor cross-section: 70 mm²
- Rated Voltage Uo/U (Um): 3.6/6 kV
FLAMEX SI EN 50382-2 3600V 95 FFS 120°C
Nexans ref. 10260430
- Packaging: Cut to length (m)
- Conductor cross-section: 95 mm²
- Rated Voltage Uo/U (Um): 3.6/6 kV
Description
Description
Standards
-
InternationalEN 45545-2 (HL3)
Application
FLAMEX SI EN 50382-2 type FFS screened power cables are used for fixed installations where enhanced mechanical protection and electrical screening (EMC) is required. The insulation and sheath are designed with state-of-the art silicone materials to withstand high operating temperature and save weight on board of rolling stock equipment. FLAMEX cables are recommended for installations and connections in narrow spaces where an optimal bending radius is required. They provide optimum safety for people and maximal asset protection against all risks of fire.
Construction
- Conductor
Flexible class 5 copper according to IEC 60228
* tinned copper for 120°C Class
* plain copper for 150°C Class - Insulation
Cross-linked silicone type EI 111 according to EN 50382-1 - Separator
Unweaved tape - Screen
Tinned copper wire braid - Separator
Unweaved tape - Outer sheath
Cross-linked silicone type EM 107 according to EN 50382-1
Colour: black outer layer
Marking
FLAMEX SI - EN 50382-2 - Voltage rate (1800V or 3600V) - cross-section mm² - FFS - temperature class (120°C or 150°C) - NEXANS 279 - week/year
Guide to use
Cabling rules are given according to EN 50343
- Minimum bending radius (static) : 4 x outer cable diameter
- Minimum bending radius (dynamic) : 6 x outer cable diameter
Pulling tensible force (dynamic) during installation : 50 N/mm² of copper size
Mechanical (static) tensible force : 15N/mm² of copper size
Permissible current carrying capacities : value and calculation method are given in EN 50355
Standards
Construction according to EN 50382-2
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Usage characteristics
Usage characteristics