FLAMEX 20 EN 50306-2 1X1.5 M

Description

Description

Standards

  • International
    EN 45545-2 (HL3); EN 50305; EN 50306

 

Strictly halogen-free, these control wires and cables combine the advantages of small size, lightweight, high chemical resistance and high mechanical properties. They are recommended for installation in all types of railway vehicles. A 125°C conductor temperature is allowed during 20,000 hours cumulative working time for EN 50306-2.

 

DESIGN

1. Conductor
Flexible stranded tinned copper

2. Insulation
Thin wall halogen-free cross-linked material acc. EN 50306-2
Colour: white

 

Example of marking:  FLAMEX 239  EN 50306-2 - 300 V - 1 x cross-section - M - week/year

 

FIRE SAFETY STANDARDS

FLAMEX® control wires are conform to EN 45545-2.

 

GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 5 x outer cable diameter
    • For installation and occasional movements: 10 x outer cable diameter

 

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tin plated copper
Conductor flexibility
Flexible stranded
Insulation
Cross-linked compound
Halogen free
EN 60754-1 & EN 60684-2
Insulation colour
White

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
1.5 mm²
Stranding (No./mm)
Conductor diameter (mm)
1.60
Minimum cable diameter
1.9 mm
Maximum cable diameter
2.3 mm
Approximate weight
16 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
300 / 300 V
Max. DC resistance of the conductor at 20°C
13.7 Ohm/km

Usage characteristics

Usage characteristics

Flame retardant
EN 60332-1-2
Fire retardant
EN 50305.9.1.2
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-40 ... 105 °C
Maximum operating temperature
105 °C
Overload maximum core temperature
125 °C
Chemical resistance
Excellent
Fire load
0.013 kWh/m

Resources

Resources

Documentation

xlsx — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close