• Contact us

FLAMEX® EN 50382-2 FX

Products

FLAMEX SI EN 50382-2 1800V 1.5 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 1.5 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 1.5 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 1.5 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 10 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 10 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 10 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 10 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 120 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 120 FX 150°C

Nexans ref. 10227163

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 150 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 150 FX 150°C

Nexans ref. 10263103

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 16 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 16 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 16 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 16 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 185 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 185 FX 150°C

Nexans ref. 10263125

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 2.5 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 2.5 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 240 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 240 FX 150°C

Nexans ref. 10227162

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 25 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 25 FX 150°C

Nexans ref. 10261507

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 300 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 300 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 35 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 35 FX 150°C

Nexans ref. 10261508

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 4 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 4 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 4 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 4 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 400 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 400 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 400 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 400 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 50 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 50 FX 150°C

Nexans ref. 10263100

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 6 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 6 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 6 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 6 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 70 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 70 FX 150°C

Nexans ref. 10263101

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 1800V 95 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 1800V 95 FX 150°C

Nexans ref. 10263102

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 10 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 10 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 10 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 10 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 120 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 120 FX 150°C

Nexans ref. 10263130

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 150 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 150 FX 150°C

Nexans ref. 10263131

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 16 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 16 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 16 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 16 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 185 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 185 FX 150°C

Nexans ref. 10227377

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 2.5 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 2.5 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 240 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 240 FX 150°C

Nexans ref. 10263132

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 25 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 25 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 300 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 300 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 35 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 35 FX 150°C

Nexans ref. 10263126

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 4 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 4 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 4 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 4 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 400 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 400 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 400 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 400 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 50 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 50 FX 150°C

Nexans ref. 10263127

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 6 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 6 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 6 FX 150°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 6 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 70 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 70 FX 150°C

Nexans ref. 10263128

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

FLAMEX SI EN 50382-2 3600V 95 FX 120°C

Nexans ref.

  • Packaging: Cut to length
  • Conductor material: Tinned copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 120 °C

FLAMEX SI EN 50382-2 3600V 95 FX 150°C

Nexans ref. 10263129

  • Packaging: Cut to length
  • Conductor material: Plain copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 3.6/6 kV
  • Max. conductor temperature in service: 150 °C

Description

Description

Standards

  • International
    EN 45545-2 (HL3); EN 50382-2

Application

These specific extra flexible cables are designed and dedicated to be used on rolling stock equipment where high temperature is required to save cable weight.

Thanks to its high flexibility, these cables are frequently installed on locomotive equipement with low bending radius.

Construction

  • Conductor
    Extra flexible class 6 copper according to IEC 60228
    * tinned copper for 120°C Class
    * plain copper for 150°C Class
  • Separator
    Unweaved tape
  • Insulation
    Cross-linked silicone type EI 111 according to EN 50382-1
    Colour : black outer layer

Marking

FLAMEX SI - EN 50382-2 - Voltage rate (1800V or 3600V) - cross-section mm² - FX - temperature class (120°C or 150°C) - NEXANS 279 - week/year

Guide to use

Cabling rules are given in EN 50343
- Minimum bending radius (static) : 4 x outer cable diameter
- Minimum bending radius (dynamic) : 6 x outer cable diameter
Mechanical static tensible force : 15N/mm² of copper size
Permissible current carrying capacities : value and calculation method are given in EN 50355

Standards

Construction according to EN 50382-2
 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Insulation
-
Halogen free
EN 50267

Usage characteristics

Usage characteristics

Chemical resistance
Good
Flame retardant
EN 60332-1-2
Fire retardant
EN 50266-2
Smoke density
EN/IEC 61034-2
Gases corrosivity
IEC 60754
Gases toxicity
EN 50305-9.2
Operating temperature, range
-50 - 120 °C

Resources

Resources

Documentation

FLAMEX SI type F png — 9.5 kB

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close