FLAMEX® EN 50382-2 F

Produkty

FLAMEX SI EN 50382-2 1800V 10F 120°C

Nexans ref. 10195311

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 10 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 10F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 10 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 120F 120°C

Nexans ref. 10207187

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 120F 150°C

Nexans ref. 10227161

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 150F 120°C

Nexans ref. 10198300

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 150F 150°C

Nexans ref. 10261513

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 16F 120°C

Nexans ref. 10211402

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 16 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 16F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 16 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 185F 120°C

Nexans ref. 10211464

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 185F 150°C

Nexans ref. 10269713

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 2.5F 120°C

Nexans ref. 10195310

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 2,5 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 2.5F 150°C

Nexans ref. 10261509

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 2,5 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 240F 120°C

Nexans ref. 10211465

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 240F 150°C

Nexans ref. 10227159

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 25F 120°C

Nexans ref. 10207155

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 25F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 300F 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 300F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 35F 120°C

Nexans ref. 10211403

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 35F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 4F 120°C

Nexans ref. 10203262

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 4 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 4F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 4 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 50F 120°C

Nexans ref. 10207186

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 50F 150°C

Nexans ref. 10261511

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 6F 120°C

Nexans ref. 10211401

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 6 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 6F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 6 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 70F 120°C

Nexans ref. 10195312

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 70F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 95F 120°C

Nexans ref. 10195313

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 95F 150°C

Nexans ref. 10261512

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 6F 150°C

Nexans ref. 10270404

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 6 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 10F 120°C

Nexans ref. 10195796

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 10 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 10F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 10 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 120F 120°C

Nexans ref. 10179833

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 120F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 150F 120°C

Nexans ref. 10179834

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 150F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 16F 120°C

Nexans ref. 10256165

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 16 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 16F 150°C

Nexans ref. 10267838

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 16 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 185F 120°C

Nexans ref. 10179835

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 185F 150°C

Nexans ref. 10227160

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 2.5F 120°C

Nexans ref. 10211467

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 2,5 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 2.5F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 2,5 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 240F 120°C

Nexans ref. 10179836

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 240F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 25F 120°C

Nexans ref. 10195124

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 25F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 300F 120°C

Nexans ref. 10281085

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 300F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 35F 120°C

Nexans ref. 10241573

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 35F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 4F 120°C

Nexans ref. 10191664

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 4 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 4F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 4 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 50F 120°C

Nexans ref. 10179832

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 50F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 6F 120°C

Nexans ref. 10211466

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 6 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 70F 120°C

Nexans ref. 10191170

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 70F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 95F 120°C

Nexans ref. 10191194

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 95F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

Popis

Popis

Normy

  • Mezinárodní
    EN 45545-2 (HL3); EN 50382-2; IEC 60228

FLAMEX® EN 50382-2 F power cables are designed and dedicated to be used on rolling stock equipment where high operating temperature is required to save cable weight. Thanks to its high flexibility, these cables with low bending radius are frequently installed on locomotive equipment.

DESIGN

1. Conductor
Flexible class 5 copper according to IEC 60228
    - tinned copper for 120°C Class
    - plain copper for 150°C Class

Separator: Unweaved tape

2. Insulation
Cross-linked silicone type EI 111 according to EN 50382-1
Colour: black outer layer

Example of marking: FLAMEX SI - EN 50382-2 - Voltage rate (1800V or 3600V) - cross-section mm² - F - temperature class (120°C or 150°C) - NEXANS 279 - week/year

 

FIRE SAFETY

FLAMEX® EN 50382-2 F power cables are conform to EN 45545-2 HL3

 

GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 4 x outer cable diameter
    • For installation and occasional movements: 6 x outer cable diameter
  • Pulling tensible force (dynamic) during installation: 50 N/mm² of copper size
  • Mechanical static tensible force: 15N/mm² of copper size

 

 

Charakteristika

Charakteristika

Konstrukční charakteristika

Konstrukční charakteristika

Conductor flexibility
Flexible class 5
Isolace
High temperature silicone
Bezhalogenové
EN 60754-1 & EN 60684-2

Charakteristika použití

Charakteristika použití

Samozhášivost
EN 60332-1-2
Fire retardant
EN 60332-3-24; EN 60332-3-25
Hustota dýmu
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-50 ... 120 °C
Chemická odolnost
Good

Zdroje

Zdroje

Kontaktujte nás

Témata, o kterých si přejete získat více informací:

Požadovaná pole*

Zkontrolujte prosím svůj údaj a zkuste to znovu

E-mailová adresa musí obsahovat jediný znak @

Ochránce osobních údajů

Máte právo vznést námitku proti zpracování svých osobních údajů a/nebo jejich použití pro přímý marketing nebo komerční účely

Děkujeme vám!

Děkujeme, že jste nás kontaktovali. Brzy se s vámi spojíme.

Chyba

Došlo k chybě. Zkuste prosím aggain.

Zavřít