These instrumentation and communication cables are used to transmit analogue or digital signals in measurement and process control. They are well adapted to underground use in industrial applications, in moist areas, where chemical and mechanical protection are needed. The lead cover brings an enhanced resistance to aromatics hydrocarbons. The individual screening of each pair limits the consequence of crosstalk.
Nexans code
Design
Conductor:
Solid plain copper 0.50 mm² (1 x 0.80 mm) or stranded plain copper cross-section 0.88 mm² (7 x 0.40 mm) 15 mm² (7 x 0.52 mm)
Insulation:
Polyvinyl chloride (PVC)
Individual screen:
Polyester tape
Tinned copper drain wire
Aluminium/polyester tape
Individual sheath:
Overall screen:
Inner sheath:
Lead covering
Armour:
Paraffin-waxed crepe paper
Double steel tape
Outer sheath:
Colour: light-blue or grey
Core identification
Pair: natural - red Triple: natural - red - blue Blue individual sheath printed with pair/triple number
Marking
GORSE - Number of pair/triple IP/IT 05/09/15 EI PF + metric marking
Minimum bending radius:
1 core: 10 x outer diameter To be doubled during laying operations