POWERMINE™ RHEYFIRM NYHSSYCY 3.6/6 kV Screened PVC Cable 3.6/6 kV
Standart
Mezinárodní  Nexans specification
Popis

Application / structure  

For underground mines as well as in tunnels, if monitoring of outer damages is required. Used for the connection of mobile operating equipment, in mines and underground excavations with hazardous environment, in stationary operation, e.g. high-voltage transformers in tunneling.

Three core screened PVC Insulated high voltage cable with flexible conductor, symmetrically split protective conductor on each core, PVC inner sheath, control-core and additional pilot cores, steel wire braid and PVC sheath.
 

 

Design

Main cores
Copper, plain, flexible stranded, acc. to DIN EN 60228 class 5
PVC compound type YI5; over insulation the protective conductor made of plain copper wires, design acc. DIN VDE 0250 part 1

Pilot cores
Copper, plain, flexible stranded acc. to DIN EN 60228 class 5
PVC compound type YI4, core colour: black with white no. 1 - 3

Inner sheath
Bedding:           plastic filling the interstices
Inner sheath:    PVC compound type YM1

Monitoring Screen
Plain copper wires, D.C. resistance: 3.3 Ohm/km at 20 °C

Inner sheath 2
Intermediate sheath of PVC compound type YM1

Armour
Galvanized steel wire braid, covering min.  75 %

Outer sheath
PVC compound type YM3


Marking

Embossed marking e.g.:
RHEYFIRM NYHSSYCY 3x95+3x50/3E+3x2.5ST+UEL 3.6/6 kV I NEXANS I
<vde>  year
 

Standards

DIN VDE 0250 part 212;  DIN VDE 0298-3 and 4; DIN VDE 0118-2
 


 Nahoře
Vlastnosti
Konstrukční charakteristika
Sheath colour Red  
Material jádra Plain copper  
Inner sheath PVC compound type YM1  
Outer sheath PVC compound type YM 3  
Electrical characteristics
Test voltage 11kV  
Mechanical characteristics
Cable flexibility Flexible  
Abrasion resistance High  
Tear resistance High  
Charakteristika použití
Field of application Tunneling, Underground  
Samozhášivost IEC 60332-1-2  
Oil resistance EN 60811-2-1  
Ozone resistance Yes  
Weather resistance Good  
RoHS conform Yes  
Silicon free Yes  
Limit surface temperature, flexible application 5 .. 70°C  
Max. conductor temperature in service 70°C  
Ambient static operating temperature, range -40 .. 70°C  
Short-circuit max. conductor temperature 150°C  

 Nahoře
Test voltage on complete cables

High voltage cores

test voltage (AC voltage)

  11 kV

min. test period 

    5 min.

Control cables

test voltage (AC voltage)

    2 kV

min. test period

    5 min.

Monitoring screen

test voltage (AC voltage)

    2 kV

min. test period

    5 min.


 Nahoře
Prodejní a dodací podmínky

Options

Further numbers of cores and cross-section upon request