About Nexans
Produkty a řešení
Služby zákazníkům
Pracovat pro Nexans
Novinky a tiskoviny
For protected installation in railway vehicles (locomotives, trains, trolley busses), switching stations and control panels. Installation in cable ducts, pipes and tubes. Current carrying capacity acc. to EN 50343 as well as VDE 0298 part 4. Serves request acc. to EN 45545-1. Fire integrity is in acc. with EN50200 (15 minutes) resp. EN 50362.
1. Conductor
Flexible stranded tinned copper, class 5 acc. to DIN VDE 0295 / IEC 60228 / HD 383, conductor wrapping optional.
2. Mica taping 3. Insulation
Double layer insulation, rubber type EI110/EI109 (EM104) acc. to EN 50264-1, oil, diesel-oil, ozone and UV-resistant
e.g.: RHEYHALON VDE-Reg.-Nr. 7904 4GKW-EN FR 1,8/3 kV EN 50264-3-1 1800V 1x25 OM FA-Nr. ...
Black (BK)
DIN 5510 part 1: Flame protection class 1, 2, 3 and 4 BS 6853 (on request)
Nominal voltage
Uo/U (Umax) = 1,8/3 (3,6) kV
Max. operating voltage (d.c.)
Vo =2,7 kV
Testing a.c. voltage (5 minutes)
U = 6,5 kV
Conductor at normal operation
≤ 90 °C/250.000 h
≤ 120 °C/20.000 h
Overload
≤ 160 °C / 50 h
Conductor under short-circuit conditions (tinned)
≤ 200 °C
Other cross-sections on request.
Special conditions relating temperature and bending radii (e.g. by compelled guidance into cluthes, wagon transition and boogies) on request.