English Slovenčina українська Přihlásit Zaregistrovat se Catalog Browser Contact Us
Globální expert na kabely a kabelové systémy

About Nexans

Produkty a řešení

Služby zákazníkům

Pracovat pro Nexans

Novinky a tiskoviny

Jdi na

RHEYHALON NSHXAFOE EN 9GKW (3.6/6 kV)

Záložka Tisknout Kontaktovat nás
RHEYHALON NSHXAFOE EN 9GKW (3.6/6 kV) EN 50264-3-1, tab. 4
Halogenfree sheathed single core cable
3,6/6 kV
Standart
Mezinárodní  EN 50264-3-1
Národní standart  BS 6853; DIN 5510-1; DIN VDE 0295; DIN VDE 0298
Popis

Applications

For inside and outside use in railway vehicles (locomotives, trains, trolley busses, etc.), switching stations and control panels. Installation in cable ducts, tubes and outside.

For wiring in switching stations and distribution boards up to 1.000 V, this cable is short-circuit and earth fault save.

Current carrying capacity acc. to EN 50343 as well as VDE 0298 part 4. Serves request with regard to Hazard Level 4 acc. to EN 45545-1

 

Design

1. Conductor

Flexible stranded tinned copper, acc. to DIN VDE 0295/IEC 60228/
HD 383 class 5; conductor wrapping optional

2. Insulation

Special cross-linked EPR, rubber type EI110 acc. to EN 50264-1

3. Outer sheath

Special cross-linked EVA, rubber type EM104 acc. to EN 50264-1,
oil, diesel-oil, ozone and uv resistant.

 

Cable marking

Ink-marking white

RHEYHALON VDE-Reg.-Nr. 7906 ; NSHXAFOE EN 3.6/6 kV 9GKW
EN 50264-3-1 3600V 2.5  MM ; FA-Nr. ...

 

Core colours

Black (BK)

Additional Standards

DIN 5510 part 1 Flame protection class 1, 2, 3 and 4
BS 6853


 Nahoře
Vlastnosti
Konstrukční charakteristika
Bezhalogenové IEC 60754-1  
Charakteristika použití
Operating temperature, range -40 .. 90°C  
Gases corrosivity No acc. to EN 50267-2-2  
Gases toxicity innocuous EN 50305-9.2  
Samozhášivost EN 60332-1-2 & EN 60332-3-24 & EN 60332-3-25  
Hustota dýmu EN/IEC 61034-2  
Bending factor when installed 6(xD)  
Bending factor when laying 10(xD)  
Oil resistance Yes  
Ozone resistance Yes  
U.V resistance Yes  

 Nahoře
Váš výběr
Colour  
Conductor cross-section  mm²
Minimum outer diameter  mm
Maximum outer diameter  mm
Fire load  kWh/m
Approximate weight  kg/km
Použít
Obnovit
Výsledky   16/16
Výběr všech položek Nexans reference Colour Conductor cross-section (mm²) Minimum outer diameter (mm) Maximum outer diameter (mm) Fire load (kWh/m) Approximate weight (kg/km)
79471341 Black 2,5 8,9 9,3 0,5 115
79471342 Black 4 9,6 10,0 0,55 130
79471343 Black 6 10,3 10,7 0,65 160
79471344 Black 10 11,4 12,0 0,75 210
79471345 Black 16 12,9 13,5 0,85 300
79471346 Black 25 14,7 15,3 1 400
79471347 Black 35 16,0 16,6 1,2 520
79471348 Black 50 17,5 18,1 1,4 650
79471349 Black 70 19,2 19,8 1,6 880
79471350 Black 95 21,5 22,1 1,9 1150
79471351 Black 120 23,5 24,1 2,2 1400
79471352 Black 150 24,7 25,5 2,4 1700
79471353 Black 185 26,9 27,7 2,6 2050
79471354 Black 240 29,5 30,3 2,9 2600
79471355 Black 300 31,7 32,5 3,6 3200
79471356 Black 400 35,8 36,6 4,1 4100
Přidat do favoritů

 Nahoře
Electrical properties

Nominal voltage 

Uo/U (Umax) = 3.6/6 (7.2) kV

Max. operating voltage in d.c. installations, one-sided earthed                                                              

Uo= 5.4 kV DC

Testing a.c. voltage (5 minutes) 

U = 12 kV


Max. operating temperature at conductor

Conductor at normal operation

≤ 90 °C/250.000 h

 

≤ 120 °C/20.000 h

Overload 

≤ 160 °C / 50 h

Conductor under short-circuit conditions (tinned)

≤ 200 °C


 Nahoře
Prodejní a dodací podmínky
  • Other cross-sections on request.
  • Special conditions relating temperature and bending radii (e.g. by compelled guidance into cluthes, wagon transition and boogies) on request.

  • Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map