RHEYHALON (N)S2HXAFCOE (3,6/6 kV)

Záložka Tisknout Kontaktovat nás
RHEYHALON (N)S2HXAFCOE (3,6/6 kV) In line with EN 50382-2 and DIN VDE 0250 part 606 E
Halogenfree, screened and sheathed single core cable for higher temperature applications
3,6/6 kV
Standart
Mezinárodní  EN 50382-2; Manufacturer specification
Národní standart  BS 6853; DIN 5510-1; DIN VDE 0250; DIN VDE 0295; DIN VDE 0298
Popis

Applications

For use in railway vehicles (locomotives, trains, trolley-busses, etc.), switching stations and control panels. Installation in cable ducts, tubes and outside.

For wiring in switching stations and distribution boards up to 1.000 V, this cable is short-circuit and earth fault save.

Current-carrying capacity acc. to EN 50343 as well as VDE 0298 part 4. Serves request with regard to Hazard Level 4 acc. to EN 45545-1

 

Design

1. Conductor 

Flexible stranded bare copper, acc. to DIN VDE 0295/IEC 60228/HD 383 class 5, conductor wrapping optional

2. Insulation 

High grade silicon type EI112 acc. to EN 50382-1

3. Separator

Foil or tape

4. Screen

Tinned copper wire braid, covering appr. 85 %

5. Separator 

Foil or tape

6. Outer sheath

High grade silicon, type EM107 acc. to EN 50382-1,
oil, diesel-oil, ozone and uv resistant 

Cable marking

Marking white:

RHEYHALON 180  (N)S2HXAFCOE   3,6/6 kV  (EN) 50382-2 3600V  1x50  OF

Core colours

yellow

Standards

DIN 5510 part 1 Flame protection class 1, 2, 3 and 4; BS 6853


 Nahoře
Vlastnosti
Konstrukční charakteristika
Bezhalogenové IEC 60754-1  
Rozměrová charakteristika
Počet jader 1  
Charakteristika použití
Operating temperature, range -65 .. 180°C  
Gases corrosivity No acc. to EN 50267-2-2  
Gases toxicity innocuous EN 50305-9.2  
Samozhášivost EN 60332-1-2 & EN 60332-3-24 & EN 60332-3-25  
Hustota dýmu EN/IEC 61034-2  
Bending factor when installed 6(xD)  
Bending factor when laying 10(xD)  
Oil resistance Yes  
Ozone resistance Yes  
U.V resistance Yes  

 Nahoře
Váš výběr
Colour  
Conductor cross-section  mm²
Diameter over braid  mm
Minimum outer diameter  mm
Maximum outer diameter  mm
Fire load  kWh/m
Approximate weight  kg/km
Použít
Obnovit
Výsledky   2/2
Výběr všech položek Nexans reference Colour Conductor cross-section (mm²) Diameter over braid (mm) Minimum outer diameter (mm) Maximum outer diameter (mm) Fire load (kWh/m) Approximate weight (kg/km)
79471084 Yellow 70 19,2 21,1 21,9 1,3 1050
79470560 Yellow 95 21,4 22,8 23,6 1,6 1350
Přidat do favoritů

 Nahoře
Electrical properties

Nominal voltage 

Uo/U (Umax) = 3.6/6 (7.2) kV

Max. operating voltage in d.c. installations, one-sided earthed                                                              

Uo= 6.5 kV DC

Testing a.c. voltage (5 minutes) 

U = 12.5 kV

Coupling resistance 10 kHz – 30 MHz: at Ø over braid   ≤ 10 mm

≤ 150 Ω/km

Coupling resistance 10 kHz – 30 MHz: at Ø over braid   > 10 mm

≤ 50 Ω/km


Max. operating temperature at conductor

Conductor at normal operation

≤ 150 °C/100.000 h

 

≤ 180 °C/20.000 h

Conductor under short-circuit conditions (tinned)

≤ 350 °C


 Nahoře
Prodejní a dodací podmínky
  • Other cross-section on request.
  • Special conditions relating temperature and bending radii (e.g. by compelled guidance into cluthes, wagon transition and boogies) on request.