MGCH 0.6/1 kV Halogen Free Power Cables with screen (armour) 0.6/1 kV
Standart
Mezinárodní  IEC 60092-353; IEC 60332-3; IEC 60754-1; IEC 60754-2; IEC 61034
Národní standart  DIN 89158/98; DIN 89158/98
Popis

Applications

For fixed installations on ships and offshore-units in all locations and open deck.

The good screening qualities of the copper braid also reduce radio interferences and electrical influences to electronic installation.

The cables meet the flame test requirement for bunched cables acc. to IEC 60332-3-22 and IEEE45-18.13, and perform to the SOLAS requirements.

All cable materials are free of halogens. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, these cables are especially suitable for the installation on passenger ships.

 

Design

  1. Conductor: Stranded bare copper class 2
  2. Insulation: HEPR (crosslinked hardgrade ethylene propylene rubber)
  3. Common covering: filler (extruded) or tape
  4. Armouring: separator tape, bare copper braid, separator tape(optional)
  5. Outer sheath: Polyolefin,
    colour:black

 

Marking

e.g.: l NEXANS l MGCH 1000 V 85 GRAD C DIN 89158, IEC 60092-353, IEC 60332-3 HALOGENFREE 9 x 1,5 + 1,5 E/10,0 mm2 + Metric Marking

 

Core Identification

1 core: natural colour ( beige )

2 cores: black / blue

3 cores: black / blue / brown

4 cores: black / blue / brown / black

5 cores: black / blue / brown / black / black

7 to 24 core cable: all cores natural coloured, printed with numbers, starting in centre with number 1.

Cables with 3 cores and above also with green-yellow core (must be stated in order).


 Nahoře
Vlastnosti
Konstrukční charakteristika
Material jádra Bare copper  
Conductor flexibility Stranded class 2  
Isolace Polyethylene/Petroleum Jelly  
Protection Filler or tape  
Outer sheath Tinned copper  
Sheath colour Black  
Bezhalogenové PE  
Armour type Bare copper braid  
Electrical characteristics
Rated Voltage Uo/U (Um) 0.6/1 kV  
Test voltage 3500V  
Charakteristika použití
Max. conductor temperature in service 85°C  
Samozhášivost IEC 60332-3 Cat. A  
Hustota dýmu IEC 61034  
Gases corrosivity No IEC 60754-2  
Gases toxicity No toxicity to IEC 60754-1  
Standard DIN VDE and IEC  

 Nahoře
Váš výběr
Počet jader  
Conductor cross-section  mm²
Minimum outer diameter  mm
Maximum outer diameter  mm
Approximate weight  kg/km
Použít
Obnovit
Výsledky   53/53
Výběr všech položek Nexans reference Jméno Počet jader Conductor cross-section (mm²) Minimum outer diameter (mm) Maximum outer diameter (mm)
25102304 MGCH 1 x 10 mm² 1 10 8,0 10,5
25103024 MGCH 1 x 120 mm² 1 120 19,5 22,5
25103124 MGCH 1 x 150 mm² 1 150 21,5 25,0
25102404 MGCH 1 x 16 mm² 1 16 9,0 11,5
25103204 MGCH 1 x 185 mm² 1 185 23,5 27,0
23103304 MGCH 1 x 240 mm² 1 240 26,5 30,0
25102524 MGCH 1 x 25 mm² 1 25 11,0 13,5
25103404 MGCH 1 x 300 mm² 1 300 29,0 32,5
25102614 MGCH 1 x 35 mm² 1 35 12,0 14,5
25102104 MGCH 1 x 4 mm² 1 4 6,0 8,5
25102724 MGCH 1 x 50 mm² 1 50 14,0 16,5
25102204 MGCH 1 x 6 mm² 1 6 7,0 9,5
25102824 MGCH 1 x 70 mm² 1 70 16,0 18,5
25102924 MGCH 1 x 95 mm² 1 95 18,0 21,0
25183704 MGCH 10 x 1.5 mm² 10 1,5 15,5 18,5
25182404 MGCH 12 x 1.5 mm² 12 1,5 16,5 19,5
25183904 MGCH 14 x 1.5 mm² 14 1,5 17,0 20,0
25182604 MGCH 16 x 1.5 mm² 16 1,5 18,5 21,0
25184104 MGCH 19 x 1.5 mm² 19 1,5 19,0 22,0
25120904 MGCH 2 x 1.5 mm² 2 1,5 10,0 12,5
25121304 MGCH 2 x 10 mm² 2 10 15,5 18,5
25121404 MGCH 2 x 16 mm² 2 16 18,0 21,0
25121004 MGCH 2 x 2.5 mm² 2 2,5 11,0 13,5
25121524 MGCH 2 x 25 mm² 2 25 20,5 24,5
25121104 MGCH 2 x 4 mm² 2 4 12,0 14,5
25121204 MGCH 2 x 6 mm² 2 6 14,0 16,5
25182805 MGCH 24 x 1.5 mm² 24 1,5 22,5 25,5
25131404 MGCH 3 x 1.5 mm² 3 1,5 10,5 13,0
25131804 MGCH 3 x 10 mm² 3 10 16,5 19,5
25132524 MGCH 3 x 120 mm² 3 120 40,5 46,0
25131904 MGCH 3 x 16 mm² 3 16 19,0 22,0
25131504 MGCH 3 x 2.5 mm² 3 2,5 11,5 14,0
25132024 MGCH 3 x 25 mm² 3 25 22,0 25,5
25132124 MGCH 3 x 35 mm² 3 35 24,5 28,5
25131604 MGCH 3 x 4 mm² 3 4 12,5 15,0
25132224 MGCH 3 x 50 mm² 3 50 28,0 31,5
25131704 MGCH 3 x 6 mm² 3 6 14,5 17,0
25132324 MGCH 3 x 70 mm² 3 70 32,5 37,0
25132424 MGCH 3 x 95 mm² 3 95 37,0 41,5
25151404 MGCH 4 x 1.5 mm² 4 1,5 11,0 13,5
25151804 MGCH 4 x 10 mm² 4 10 18,0 21,0
25151904 MGCH 4 x 16 mm² 4 16 20,5 24,0
25151504 MGCH 4 x 2.5 mm² 4 2,5 12,5 16,0
25132024 MGCH 4 x 25 mm² 4 25 24,5 28,0
25132114 MGCH 4 x 35 mm² 4 35 27,0 31,0
25151604 MGCH 4 x 4 mm² 4 4 14,0 16,5
25132204 MGCH 4 x 50 mm² 4 50 30,5 35,5
25151704 MGCH 4 x 6 mm² 4 6 15,5 18,5
25152304 MGCH 4 x 70 mm² 4 70 36,5 41,0
25152424 MGCH 4 x 95 mm² 4 95 41,5 46,0
25170104 MGCH 5 x 1.5 mm² 5 1,5 12,0 14,5
25170304 MGCH 5 x 2.5 mm² 5 2,5 14,0 16,5
25182204 MGCH 7 x 1.5 mm² 7 1,5 13,0 15,5
Přidat do favoritů

 Nahoře
Additional Cable Characteristics

Minimum internal bending radius

 

- for all cables 

6 x cable diameter

 

 

Current ratings for continuous operation and further hints for cable installation

 

are according to IEC 60092-352

 


Approval

Type Approval Certificates   

 

• American Bureau of Shipping

 

• Bureau Veritas

 

• Det Norske Veritas 

 

• Germanischer Lloyd

 

• Lloyd´s Register of Shipping

 