English Slovenčina українська Přihlásit Zaregistrovat se Catalog Browser Contact Us
Globální expert na kabely a kabelové systémy

About Nexans

Produkty a řešení

Služby zákazníkům

Pracovat pro Nexans

Novinky a tiskoviny

Jdi na

LANsense EMAC Products

Záložka Tisknout Kontaktovat nás
LANsense EMAC Products EMAC Products
LANsense
Standart
Mezinárodní  Nexans specification
Popis

Corporate data centres are well known as significant power users, with a large sized data centre consuming similar amounts of power to an average sized town. As data centres today generate more heat output and often suffer from inadequate cooling, the need to operate efficiently and cost effectively against infrastructure and power constraints is increasing.

Obviously the greater capacity required, the greater impact on ensuring continuity of supply.  Add to this, the escalating cost of energy, and the requirement for management information and control becomes evermore critical.

Nexans provides a range of standard intelligent power management capabilities, for both new and existing builds specified for both power monitoring only, or a combination of power monitoring with individual outlet control.

Defined upper and lower thresholds allow the client to differentiate between warning and critical status, generating various alarms and alerts, with appropriate escalation paths.

Aggregation of configuration information across data centre equipment, for intelligent monitoring and alarm processing, provides ‘real time’ identification of changes, scheduled polling and the ability to capture detailed data to produce highly sophisticated and graphical management information reports, enabling clients to perform trend analysis and risk management for mission critical services.

Status information can be gathered either locally or remotely via secure authenticated IP access (LDAP) monitoring RMS volts, amps, kVA, kWh, power factor and frequency. 

Detailed values and management information across device location, power and cooling, network connectivity, asset application and customer information enable us to present analysis on current and historical trending. This trend analysis can be further utilised to help CIOs make informed decisions on capacity planning, risk analysis, performance benchmarking and policing service level agreements.

To optimise both power consumption and energy use, our intelligent offerings make it possible to meter actual power usage and produce trend data for any single or group of physical systems, enabling:

  • Adequate capacity for existing & future needs
  • Monitoring, measuring & reporting of power usage via multiple clients
  • Billing stream capability for hosted clients
  • Prevention of unauthorised use of power outlets / equipment deployment
  • System load management (phase balancing, capacity planning etc)
  • Recovery of locked servers via remote IP power cycling
  • Alarming & trending of system, rack, powerstrip and outlet level overload conditions.

 Nahoře
Vlastnosti
Charakteristika použití
RoHS conform Yes  

 Nahoře
Výsledky   16/16
Výběr všech položek Nexans reference Jméno
N878.21220 LANsense Dual Supply Link Box 32A
N878.32001 LANsense Humidity Sensor 2m
N878.32002   New LANsense Humidity Sensor RJ45
N878.41004   New LANsense Magnetic Door Sensor RJ45 4m
N878.41001 LANsense Microswitch Door Sensor 4m
N878.41003   New LANsense Microswitch Door Sensor RJ45 2m
N878.NIPM   New LANsense Non-Invasive Power Monitor
N878.22110 LANsense PDU 32A 12x10A IEC C13 Horizontal
N878.24210 LANsense PDU 32A 16x10A IEC C13 Monitor and Control
N878.22210 LANsense PDU 32A 16x10A IEC C13 Vertical
N878.22215 LANsense PDU 32A 24x10A IEC C13 Vertical
N878.11002   New LANsense Rack Manager II 6 Channel Autosensing
N878.11003   New LANsense Row Controller 12 Channel Autosensing
N878.11004   New LANsense Row Controller Expansion Module
N878.31001 LANsense Temperature Sensor 2m
N878.31002   New LANsense Temperature Sensor RJ45 2m
Přidat do favoritů

 Nahoře
Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map