UIC 9-core Screened multicore control cable with data bus, flame retardant, halogen free, as UIC connector cable 9-core
Popis

Design 4 cores with 10 mm²

Combined element

3 cores (with Cu-strand 2 x 6 mm²,  2.5 mm²) were twisted with a filling element to a combined element

wrapping: minimum one layer of plastic-foil overlapped

element sheath: TPE

UIC Data Bus 0,75 mm²

Two cross-linked wires with copper strands, 0.75 mm²/ 19 with foam-skin

polyethylene insulation, were stranded together with two fillers to a pair.

wrapping: minimum one layer of plastic-foil overlapped tinned copper braid, optical coverage > 90 %

separating layer: plastic foil, wrapped overlapped

element sheath: TPE

wrapping: non woven tape overlapped

Stranding
4 cores a were twisted to a core together with b, the UIC data bus c and two fillers
 

Core wrapping
Non woven tape overlapped
 

Outer sheath
Cross-linked, halogen free, flame retardant outer sheath
 

colour: black

 

 

 

Cable marking

Continous printing in contrasting colours [ manufacturer identification ] + type identification resp. manufacturers' identification thread

Core colours

core colours in the pair: white, black

Standards

DIN 5510 part 1

Hazard level 1 - 4
 


 Nahoře
Vlastnosti
Rozměrová charakteristika
Outer Diameter 25mm  

 Nahoře
Váš výběr
Number of core wires (nb x mm Ø)  
Použít
Obnovit
Výsledky   2/2 Ukázat celý seznam
Výběr všech položek Nexans reference Number of core wires (nb x mm Ø)
45953310   New 4 x 10 mm Ø + 2 x 16 mm Ø + 1 x 2.5 mm Ø + 2 x 0.75 mm Ø
Přidat do favoritů

 Nahoře
UIC 9-core

Properties

 

Requirements

Test according to

Electrical Properties

UIC Data Bus 0.75mm²

test voltage

core / core

2000 Veff

EN 50289-1-3

 

core / screen

1500 Veff

 50 Hz, 1 min

conductor resistance 

 

≤ 26.7 Ohm/ km

EN 50289-1-2

Mean characteristic impedance

1.0 - 10 MHz

(120 +/- 12) Ohm

IEC 61196-1 part 11.8.1

Attenuation

1.0 MHz

≤ 1.0 dB / 100m

EN 50289-1-8

1.5 MHz

≤ 1.3 dB / 100m

 

2.0 MHz

≤ 1.4 dB / 100m

 

3.0 MHz

≤ 1.8 dB / 100m

 

Electrical properties

Control cores ( 2.5 - 10 mm²)

test voltage

core / core

2000 Veff

EN 50289-1-3

core / screen

1500 Veff

 50 Hz, 1 min

conductor resistance

10 mm²

≤ 1.95 Ohm/ km

EN 50289-1-8

 

6 mm²

≤ 3.39 Ohm/ km

 

 

2.5 mm²

≤ 8.21 Ohm/ km

 

Minimum admissible bending radii

single bending

6 x D

multiple bending

12 x D

max. admissible tensile strength

50 N / mm² Conductor cross-section

D = cable diameter