About Nexans
Produkty a řešení
Služby zákazníkům
Pracovat pro Nexans
Novinky a tiskoviny
Application
As a control cable in railway rolling stock with mineral oil and fuel resistance. With reference to EN 50306 – 4 with profile MM and with reference to cable class P.
Cable marking Example
A three core control cable with 1,0 mm² conductor cross-section, halogen free core insulation, a copper braid and a halogen free, flame retardant outer sheath, is designated as:
3 MAZ 1,0 C HXOE
Core colours
up to 10 cores colored; Core: 1 - white, 2 - brown, 3 - blue, 4 - black, 5 - red, 6 - yellow, 7 - green, 8 - grey, 9 - orange, 10 - violet; >10 cores: all cores white with numbers marking.
Standards
DIN 5510 part 1
Hazard level 1 - 4
Maximum admissible operating temperature at the conductor
Conductor in operation
≤ 90°C / 100,000 h
Application in cold areas
> - 40°C
Minimum admissible bending radii
fixed installation
D ≤ 12 mm ≥ 3 D
D > 12 mm ≥ 4 D
operation caused movement
D ≤ 12 mm ≥ 5 D
D > 12 mm ≥ 6 D
D = cable diameter
Operational Conditions
nominal voltage
3000 V
test alternating voltage ( core / core ) 1 minute
2000 V / AC
current carrying capacity
according to EN 50 343