AFNOR NF M 87-201 IOS Lead Covered Armoured (EIPF)

Záložka Tisknout Kontaktovat nás
AFNOR NF M 87-201 IOS Lead Covered Armoured (EIPF) - Thermocouple cables 250V
- Individual & Overall Screen (IOS)
- Hydrocarbons resistant and enhanced resistance to aromatics.
Standart
Mezinárodní  IEC 60332-1-2; IEC 60584-3
Národní standart  NF C 32-070/C2; NF C 42-324
Popis

Applications

These compensation and extension cables are used with thermocouples for temperature measurements . They are well adapted to underground use in industrial applications, in moist areas, where chemical and mechanical protections are needed. The lead cover brings an enhanced resistance to aromatic hydrocarbons. The individual screening of each pair limits the consequence of crosstalk.

 

Design

Conductor:

Metal in accordance with the thermocouple, solid cross-section 0.50 mm² (1 x 0.80 mm)

Insulation:

Polyvinyl chloride (PVC)

Individual screen:

Polyester tape

Tinned copper drain wire

Aluminium/polyester tape

Individual sheath:

Polyvinyl chloride (PVC)

Collective screen:

Polyester tape

Tinned copper drain wire

Aluminium/polyester tape

Inner sheath:

Polyvinyl chloride (PVC)

Lead cover

Armour:

Paraffin-waxed crepe paper

Double steel tape

Outer sheath:

Polyvinyl chloride (PVC)

Colour: depends on thermocouple type

  

Core identification

See document "Identification sheet"

Individual sheath printed with pair mumber

 

Standards

NF M 87201

 

Marking

For type JC - TC - EC - KC - BC: type - (Class) - Nber of pairs & cross-section - GORSE + metric marking

For type KCA - KCB - NC - SCA - SCB - RCA - RCB (IEC 60584-3): IEC - type - (Class) - Nber of pairs & cross-section - GORSE + metric marking



Related documents
  Identification sheet/Identification  (151.1kb)



 Nahoře
Vlastnosti
Konstrukční charakteristika
Isolace PVC  
Individual screen Tinned copper drain wire + aluminium/polyester tape  
Individual sheath PVC  
Overall screen Tinned copper drain wire + aluminium/polyester tape  
Inner sheath PVC  
Lead Sheath Yes  
Armour type Two steel tapes  
Outer sheath Tight buffer  
Protection Yes  
Electrical characteristics
Operating voltage 250V  
Mechanical characteristics
Mechanical resistance to impacts Good  
Charakteristika použití
Samozhášivost NFC 32070 C2, IEC 60332-1-2  
Chemická odolnost Hydrocarbons resistant and enhanced resistances to aromatics  
Electro magnetic interference resistance Yes  
Operating temperature, range -20 .. 60°C  
Max. conductor temperature in service 70°C  
Standard NFM  

 Nahoře
Váš výběr
Conductor cross-section  mm²
Number of pairs  
Použít
Obnovit
Výsledky   5/5
Výběr všech položek Nexans reference Jméno Conductor cross-section (mm²) Number of pairs
Produkt na objednávku 03 * 05 EI PF 0,5 3
Produkt na objednávku 07 * 05 EI PF 0,5 7
Produkt na objednávku 12 * 05 EI PF 0,5 12
Produkt na objednávku 19 * 05 EI PF 0,5 19
Produkt na objednávku 27 * 05 EI PF 0,5 27
Přidat do favoritů

 Nahoře
* Thermocouple type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC  – Copper/copper nickel for copper/copper nickel thermocouple

 

 

 

 

 

 

 

JC   – Iron/copper nickel for iron/copper nickel thermocouple

 

 

 

 

 

 

 

EC  – Nickel chromium/copper nickel for nickel chromium/copper nickel thermocouple

 

 

 

 

 

 

 

KC  – Nickel chromium/nickel aluminium for nickel chromium/nickel aluminium thermocouple

 

 

 

 

 

 

 

KCA  – Iron/copper nickel for nickel chromium/nickel aluminium thermocouple

 

 

 

 

 

 

 

KCB  – Copper/copper nickel for nickel chromium/nickel aluminium thermocouple

 

 

 

 

 

 

 

NC  – Nickel chromium silicium/nickel silicium for nickel chromium silicium/nickel silicium thermocouple

 

 

 

 

 

 

 

SC RC – Copper/copper nickel for platinium rhodium thermocouple

 

 

 

 

 

 

 

BC  – Copper/copper alloy for platinium rhodium/platinium rhodium thermocouple

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 Nahoře
Prodejní a dodací podmínky

Minimum bending radius:

10 x outer diameter
To be doubled during laying operations


Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map