About Nexans
Produkty a řešení
Služby zákazníkům
Pracovat pro Nexans
Novinky a tiskoviny
For fixed installations on ships and offshore-units in all locations below the upper metallic deck.
A more specific design (e. g. screening) is necessary for installations in radio stations or above the upper metallic deck.
The cables meet the flame test requirements for bunched cables acc. to IEC 60332-3 and IEEE 45-18.13, and perform to the SOLAS requirements.
All cables materials are free of halogens. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, these cables are especially suitable for the installation on passenger ships.
e. g.: l NEXANS l MGH 1000 V DIN 89160, IEC 60092-353 IEC 60332-3-22 HALOGENFREE 2 x 25 mm2+ Metric Marking
Core Identification
1 core: natural colour ( beige )
2 cores: black / blue
3 cores: black / blue / brown
4 cores: black / blue / brown / black
5 cores: black / blue / brown / black / black
7 to 24 core cable: all cores natural coloured, printed with numbers, starting in centre with number 1.
Cables with 3 cores and above also with green-yellow core (must be stated in order).
Type Approval Certificates
• American Bureau of Shipping
• Bureau Veritas
• Det Norske Veritas
• Germanischer Lloyd
• Lloyd´s Register of Shipping
Minimum internal bending radius
- for overall diameter of cables ≤ 25 mm
4 x cable diameter
- for overall diameter of cables > 25 mm
6 x cable diameter
Current ratings for continuous operation and further hints for cable installation
are according to IEC 60092-352