For fixed installations in communication, radio, control, anddata processing facilities on ships and offshore units in alllocations and on open decks.
The cables meet the flame test requirements for bunched cablesacc. to IEC 60332-3 and IEEE45-18.13., and perform to the SOLASrequirements.
e.g.: l NEXANS l FMGCG DIN 89159 /250 V 85°C IEC 60092-375 IEC 60332-3-22 19x2x0,75 mm2 + Metric Marking
All cores are light grey The cores or each pair are printed with same numbers, starting in centre with number 1
Minimum internal bending radius
- For all diameter
6 x cable diameter
Conductor resistance
≤ 26.0 Ohm / km
Insulation resistance
> 1100 MOhm x km
Crosstalk attenuation at 100 kHz
80 dB
Inductance
approx. 0.7 mH / km
Transfer impedance at 10 MHz
1- and 2- pair cable
< 80 mOhm / m
4-pair cable
< 60 mOhm / m
7- to 24-pair cable
< 50 mOhm / m
Current ratings for continuous operation and further hints for cable installation
are according to IEC 60092-352