POWERMINE™ RHEYFIRM N3GHSSYCY 3.6/6 kV and 6/10 kV

Záložka Tisknout Kontaktovat nás
POWERMINE™ RHEYFIRM N3GHSSYCY 3.6/6 kV and 6/10 kV Screened rubber insulated / PVC sheated cable
Standart
Národní standart  DIN VDE 0118; DIN VDE 0250 part 605; DIN VDE 0298 part 4; DIN VDE 0298 part 3
Popis

Application

For underground mines as well as in tunnels, if monitoring of outer damages is required. Used for the connection of mobile operating equipment, in mines and underground excavations with hazardous environment, in stationary operation e.g., high-voltage transformers in tunnelling.
PVC inner sheath, control-core and additional pilot cores, steel wire braid and PVC sheath.

 

Design

Phase cores

Copper, plain, flexible stranded acc. to DIN EN 60228 class 5;

 - inner semi-conductive stress control layer
 - EPR-rubber insulation acc. DIN VDE 0207 part 20
 - outer semi-conductive insulation shield layer

Protective conductor

Cross-section symmetrically split on each core made of plain copper wires, covering min. 80 %, colour: black with white no.1-3

Pilot cores

Copper, plain, flexible stranded acc. to DIN EN 60228 class 5, EPR-rubber core colour coding acc. DIN VDE 0293-308

Inner sheath 1

Bedding with plastic or elastic material filling the interstices and PVC sheath

Concentrical monitoring screen

Plain copper wires, DC resistance 3.30 Ohm/km at 20 °C

Inner sheath 2

PVC compound type DMV6 acc. to DIN VDE 0276-603

Armour

galvanized steel wire braid, covering min. 75 %

Outer sheath

PVC compound type DMV6 acc. to DIN VDE 0276-603

 

Marking

Embossed marking e.g.:
RHEYFIRM N3GHSSYCY 3x95+3x50/3E+3x2.5ST+UEL 3.6/6 kV  I NEXANS I
< VDE > year


 Nahoře
Vlastnosti
Konstrukční charakteristika
Sheath colour Red  
Material jádra Plain copper  
Conductor flexibility Stranded  
Material of bedding Plastic compound  
Isolace EPR  
Inner sheath PVC  
Outer sheath PVC  
Concentric conductor Plain copper wires  
Armour type Galvanized steel wires  
Charakteristika použití
Samozhášivost EN 60332-1-2  
Short-circuit max. conductor temperature 250°C  
Max. conductor temperature in service 90°C  
Limit surface temperature fixed installed -40 .. 80°C  
Limit surface temperature, flexible application 5 .. 80°C  
Bending factor when installed 5(xD)  
Dynamic bending factor 5(xD)  
RoHS conform Yes  

 Nahoře
Váš výběr
Construction type  
Rated Voltage Uo/U (Um)  
Cable Diameter, range  mm
Approximate weight  kg/km
Použít
Obnovit
Výsledky   5/5
Výběr všech položek Nexans reference Jméno Construction type Rated Voltage Uo/U (Um) Cable Diameter, range (mm) Approximate weight (kg/km)
71160100 3x25 + 3x16 / 3E + 3x2,5ST + UEL 3x25+3x16/3E+3x2.5ST+UEL 3.6 / 6 (7.2) kV 43 .. 47 3100
71160101 3x35 + 3x16 / 3E + 3x2,5 St + UEL 3x35+3x16/3E+3x2.5ST+UEL 3.6 / 6 (7.2) kV 45 .. 49 3600
71160102 3x50 + 3x25 / 3E + 3x2,5 St + UEL 3x50+3x25/3E+3x2.5ST+UEL 3.6 / 6 (7.2) kV 49 .. 53 4450
71160103 3x70 + 3x35 / 3E + 3x2,5 St + UEL 3x70+3x35/3E+3x2.5ST+UEL 3.6 / 6 (7.2) kV 52 .. 56 5400
71160104 3x95 + 3x50 / 3E + 3x2,5 St + UEL 3x95+3x50/3E+3x2.5ST+UEL 3.6 / 6 (7.2) kV 57 .. 61 6550
Přidat do favoritů

 Nahoře
Prodejní a dodací podmínky

Special designs

For example cables to international specification, also with deviating monitoring systems

Cable fittings

Cables can be supplied with compatible sealing ends, if required (test certificate incl.)

Further details upon request


Související informace
POWERMINE™ RHEYFIRM N3GHSSYCY 3.6/6 kV and 6/10 kV   Letter code (55 kB)
POWERMINE™ RHEYFIRM N3GHSSYCY 3.6/6 kV and 6/10 kV   Electrical data (62 kB)

Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map