About Nexans
Produkty a řešení
Služby zákazníkům
Pracovat pro Nexans
Novinky a tiskoviny
For fixed installations in communication, radio, control anddata processing facilities on ships and offshore units in alllocations and on open decks.
The cables meet the flame test requirements for bunched cablesacc.to IEC 60332-3 and IEEE 45-18.13, and perform to the SOLASrequirements.
All cable materials are free of halogens. This design ensuresthat non corrosive and low toxic gases emitted in case of fire.Therefore, these cables are especially suitable for installation onpassenger ships.
e.g.: l NEXANS l FMGCH 250 V 85°C DIN 89159 IEC 60092-375 IEC 60332-3-22 HALOGENFREE 19x2x0,75 mm2 + Metric Marking
Colours of each pair: white/blue. The cores or each pair are printed with same numbers, starting in centre with number 1.
Minimum internal bending radius
- For all diameter
6 x cable diameter
Conductor resistance
≤ 26.0 Ohm / km
Insulation resistance
> 1100 MOhm x km
Transfer impedance at 10 MHz
1- and 2- pair cable
< 80 mOhm / m
4-pair cable
< 60 mOhm / m
7- to 24-pair cable
< 50 mOhm / m
Current ratings for continuous operation and further hints for cable installation
are according to IEC 60092-352
Type Approval Certificates
• American Bureau of Shipping
• Bureau Veritas
• Det Norske Veritas
• Germanischer Lloyd
• Lloyd´s Register of Shipping
• Registro Italiano Navale (pending)
• Russian Maritime Register of Shipping