NEK 606

Záložka Kontaktovat nás

  • LV-MV power
  • Instrumentation
  • LAN offshore
  • Telecom
  • Accessories

Nexans Products
Název produktu   PDF file
0.6/1KV BU Multi Core [P17]
Offshore - topside cables/Instrumentation and control cables
  • Power circuit below 1kV, Fire fighting circuit and safety systems.
  • Fixed installation power, control & lighting in safe areas, emergency and critical systems.
  • Maximum operating conductor temperature 90°C
 
0.6/1KV RU Multi Core [P18]
Offshore - topside cables/Instrumentation and control cables
  • Power circuit below 1kV, Trace heating circuits.
  • Fixed installation power, control & lighting in safe areas, general purposes.
  • Maximum operating conductor temperature 90°C
 
0.6/1kV BFOU MULTI CORE [P5], [P5/P12]
Offshore - topside cables/Instrumentation and control cables
  • Power circuit below 1kV, Fire fighting circuit and safety systems.
  • Fixed installation power, control & lighting in both explosion and safe areas, emergency and critical systems.
  • Maximum operating conductor temperature 90°C
 
0.6/1kV RFOU MULTI CORE [P1], [P1/P8]
Offshore - topside cables/Instrumentation and control cables
  • Control circuit below 1kV, Control circuits for motor starter, electrical control system, interconnecting.
  • Fixed installation power, control & lighting both explosion risk and safe areas, general purposes.
  • Maximum operating conductor temperature 90°C
 
250V BFOU(C) 0.75SQMMxPR type [S4], [S4/S8]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, emergency and critical systems.
  • Maximum operating conductor temperature 90°C
 
250V BFOU(C) 0.75SQMMxTR type [S4], [S4/S8]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, emergency and critical systems.
  • Maximum operating conductor temperature 90°C
 
250V BFOU(C) 1.0, 1.5, 2.5SQMMxPR type [S4], [S4/S8]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, emergency and critical systems.
  • Maximum operating conductor temperature 90°C
 
250V BFOU(C) 1.0, 1.5, 2.5SQMMxTR type [S4], [S4/S8]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, emergency and critical systems.
  • Maximum operating conductor temperature 90°C
 
250V BFOU(I), BFOU(I/C) 0.75SQMMxPR type [S3], [S3/S7], [MR]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, emergency and critical systems.
  • Maximum operating conductor temperature 90°C
 
250V BFOU(I), BFOU(I/C) 0.75SQMMxTR type [S3], [S3/S7], [MR]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, emergency and critical systems.
  • Maximum operating conductor temperature 90°C
 
250V BFOU(I), BFOU(I/C) 1.0, 1.5, 2.5SQMMxPR type [S3], [S3/S7], [MR]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, emergency and critical systems.
  • Maximum operating conductor temperature 90°C
 
250V BFOU(I), BFOU(I/C) 1.0, 1.5, 2.5SQMMxTR type [S3], [S3/S7], [MR]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, emergency and critical systems.
  • Maximum operating conductor temperature 90°C
 
250V RFOU(C) 0.75SQMMxPR type [S2], [S2/S6]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, general purposes.
  • Maximum operating conductor temperature 90°C
 
250V RFOU(C) 0.75SQMMxTR type [S2], [S2/S6]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, general purposes.
  • Maximum operating conductor temperature 90°C
 
250V RFOU(C) 1.0, 1.5, 2.5SQMMxPR type [S2], [S2/S6]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, general purposes.
  • Maximum operating conductor temperature 90°C
 
250V RFOU(C) 1.0, 1.5, 2.5SQMMxTR type [S2], [S2/S6]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, general purposes.
  • Maximum operating conductor temperature 90°C
 
250V RFOU(I), RFOU(I/C) 0.75SQMMxPR type [S1], [S1/S5], [MR]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, general purposes.
  • Maximum operating conductor temperature 90°C
 
250V RFOU(I), RFOU(I/C) 0.75SQMMxTR type [S1], [S1/S5], [MR]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, general purposes.
  • Maximum operating conductor temperature 90°C
 
250V RFOU(I), RFOU(I/C) 1.0, 1.5, 2.5SQMMxPR type [S1], [S1/S5], [MR]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, general purposes.
  • Maximum operating conductor temperature 90°C
 
250V RFOU(I), RFOU(I/C) 1.0, 1.5, 2.5SQMMxTR type [S1], [S1/S5], [MR]
Offshore - topside cables/Instrumentation and control cables
  • Instrument circuit up to 250V, instrument safe systems.
  • Fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, general purposes.
  • Maximum operating conductor temperature 90°C
 