English Slovenčina українська Přihlásit Zaregistrovat se Catalog Browser Contact Us
Globální expert na kabely a kabelové systémy

About Nexans

Produkty a řešení

Služby zákazníkům

Pracovat pro Nexans

Novinky a tiskoviny

Jdi na

RHEYHALON 4GKW-EN 1,8/3(3,6)kV

Záložka Tisknout Kontaktovat nás
RHEYHALON 4GKW-EN 1,8/3(3,6)kV EN 50264-3-1, tab. 2
Halogenfree single core cable
1,8/3 kV
Standart
Mezinárodní  EN 50264-3-1
Národní standart  BS 6853; DIN 5510-1; DIN VDE 0295; DIN VDE 0298
Popis

Applications

For protected installation in railway vehicles (locomotives, trains, trolley busses), switching stations and control panels. Installation in cable ducts, pipes and tubes.
Current carrying capacity acc. to EN 50343 as well as VDE 0298 part 4.
Serves request acc. to EN 45545-1.

 

Design

1. Conductor

Flexible stranded tinned copper, class 5 acc. to DIN VDE 0295 / IEC 60228
/ HD 383, conductor wrapping optional.

2. Insulation

Double layer insulation, rubber type EI110/EI109 (EM104)  acc. to EN 50264-1,
oil, diesel-oil, ozone and UV-resistant

 

Cable marking

e.g.:    RHEYHALON VDE-Reg.-Nr. 7904 4GKW-EN 1,8/3 kV EN 50264-3-1 
           1800V  1x25 OM  FA-Nr. ...
 

Core colours

Black (BK)
 

Additional standards

DIN 5510 part 1: Flame protection class 1, 2, 3 and 4
BS 6853 (on request)


 Nahoře
Vlastnosti
Konstrukční charakteristika
Bezhalogenové IEC 60754-1  
Charakteristika použití
Operating temperature, range -40 .. 90°C  
Gases corrosivity No acc. to EN 50267-2-2  
Gases toxicity innocuous EN 50305-9.2  
Samozhášivost EN 60332-1-2 & EN 60332-3-24 & EN 60332-3-25  
Hustota dýmu EN/IEC 61034-2  
Standard EN  
Bending factor when installed 5(xD)  
Bending factor when laying 10(xD)  
Oil resistance Yes  
Ozone resistance Yes  
U.V resistance Yes  

 Nahoře
Váš výběr
Colour  
Conductor cross-section  mm²
Minimum outer diameter  mm
Maximum outer diameter  mm
Fire load  kWh/m
Approximate weight  kg/km
Použít
Obnovit
Výsledky   11/11
Výběr všech položek Nexans reference Colour Conductor cross-section (mm²) Minimum outer diameter (mm) Maximum outer diameter (mm) Fire load (kWh/m) Approximate weight (kg/km)
79471306 Black 25 10,3 10,9 0,4 290
79471307 Black 35 11,4 12,0 0,46 400
79471308 Black 50 13,3 13,9 0,6 550
79471309 Black 70 15,3 15,9 0,75 750
79471310 Black 95 17,0 17,6 0,85 970
79471311 Black 120 19,3 19,9 1,1 1250
79471312 Black 150 21,6 22,2 1,35 1550
79471313 Black 185 23,5 24,1 1,5 1900
79471314 Black 240 26,6 27,2 1,9 2450
79471315 Black 300 29,3 30,1 2,2 3050
79471316 Black 400 34,1 34,9 3,5 4000
Přidat do favoritů

 Nahoře
Electrical properties

Nominal voltage 

Uo/U (Umax) = 1,8/3 (3,6) kV

Max. operating voltage (d.c.)                                                         

Vo =2,7 kV 

Testing a.c. voltage (5 minutes)

U = 6,5 kV


Max. operating temperature at conductor

Conductor at normal operation

≤ 90 °C/250.000 h

 

≤ 120 °C/20.000 h

Overload 

≤ 160 °C / 50 h

Conductor under short-circuit conditions (tinned)

≤ 200 °C


 Nahoře
Prodejní a dodací podmínky
  • Other cross-sections on request.

  • Special conditions relating temperature and bending radii (e.g. by compelled guidance into cluthes, wagon transition and boogies) on request.


  • Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map