English Slovenčina українська Přihlásit Zaregistrovat se Catalog Browser Contact Us
Globální expert na kabely a kabelové systémy

About Nexans

Produkty a řešení

Služby zákazníkům

Pracovat pro Nexans

Novinky a tiskoviny

Jdi na

ELCURAIL TAZ (300 V)

Záložka Tisknout Kontaktovat nás
ELCURAIL TAZ (300 V) Cables for Rolling Stock
Standart
Mezinárodní  EN 50267-2-1; EN 50267-2-2; EN 50268-2; EN 50305; EN 50306-2.1; EN 50343; EN 60684-2
Národní standart  DIN 5510-1
Popis

Application

For the internal wiring of equipment in railway rolling stock. Thinwall-Wiring for electronic equipment. Current carrying capacity according to EN 50343.

Cable Marking

Continuos printing in contrasting colors [manufacturer identification] + type identification

Standards

DIN 5510 part 1

Hazard level 1 - 4


 Nahoře
Vlastnosti
Konstrukční charakteristika
Bezhalogenové EN 50267-2-1 & EN 60684-2  
Material jádra Tinned copper  
Isolace High-Tech Polymer  
Conductor flexibility Fine stranded  
Electrical characteristics
Rated Voltage Uo/U (Um) 300 V  
Charakteristika použití
Max. conductor temperature in service 105°C  
Gases corrosivity No acc. to EN 50267-2-2  
Gases toxicity innocuous EN 50305  
Samozhášivost EN 50305  
Hustota dýmu EN 50268-2  

 Nahoře
Váš výběr
Conductor cross-section  mm²
Max. DC resistance of the conductor at 20°C  Ohm/km
Conductor diameter, range  mm
Minimum insulation thickness  mm
Total number of wires  
Minimum outer diameter  mm
Maximum outer diameter  mm
Approximate weight  kg/km
Fire load  kWh/m
Použít
Obnovit
Výsledky   5/5
Výběr všech položek Nexans reference Conductor cross-section (mm²) Max. DC resistance of the conductor at 20°C (Ohm/km) Conductor diameter, range (mm) Minimum insulation thickness (mm) Total number of wires Minimum outer diameter (mm) Maximum outer diameter (mm) Approximate weight (kg/km)
455705 0,5 40,1 0,8 .. 0,95 0,18 19 1,8 1,45 5
455706 0,75 26,7 1 .. 1,15 0,18 19 1,65 1,65 8
455707 1 20 1,1 .. 1,3 0,18 19 1,8 1,8 10
455708 1,5 13,7 1,45 .. 1,65 0,22 37 2,3 2,3 15
455709 2,5 8,21 1,85 .. 2,15 0,28 37 2,85 2,85 26
Přidat do favoritů

 Nahoře
Temperature/ radii

Maximum admissible operating temperature at conductor

 

Conductor in operation: 

≤ 105°C/ 100,000 h

Minimum admissible bending radii

 

Implementation

D ≥2 D

fixed installation

D ≥ 3 D

D = cable diameter

 

 

 

 

 


 Nahoře
Prodejní a dodací podmínky
  • All tests were arranged on representative samples.
  • This cable is neither useful for multiple bending nor for torsion. If needed any single case must be decided.

  • Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map