Application As a control cable in railway rolling stock with mineral oil and fuel resistance. With reference to EN 50306 – 4 with profile MM and with reference to cable class P.
Cable marking Printing in contrasting colour Example x NEXANS x 3MAZ1,0+HXOE ELCURAIL ww / jj* (* ww=week jj =year) At intervals of max. 500 mm, from the beginning of the printing to the beginning of the next printing. The durability of printing is tested according to EN 50305 part 10.1. If there is no marking a coloured company tracer thread is used.
Core colours Multicore Up to ten cores the single cores are coloured, for more than ten cores the core colour is white with numbers. Multipair Up to four pairs the cores are coloured, for more than four pairs the cores are white with numbers.
Printing is in acc. to EN 50334. The constant of printing will be tested in accordance to EN 50305 part 10.1.
Standards
DIN 5510 part 1
Hazard level 1 - 4
Design
Conductor: tinned copper, finely stranded
Insulation: Cross-linked special polymere
Cores: Stranding in layers
Seperator: Foil or band
Outer sheath: Cross-linked, mineral oil and fuel resistant HFFR Compound
Maximum admissible operating temperature at the conductor
Conductor in operation
≤ 90°C / 100,000 h
Application in cold areas
> - 40°C
Minimum admissible bending radii
fixed installation
D ≤ 12 mm ≥ 3 D
D > 12 mm ≥ 4 D
operation caused movement
D ≤ 12 mm ≥ 5 D
D > 12 mm ≥ 6 D
D = cable diameter
Operational Conditions
nominal voltage
3000 V
test alternating voltage ( core / core ) 1 minute
2000 V / AC
current carrying capacity
according to EN 50 343