English Slovenčina українська Přihlásit Zaregistrovat se Catalog Browser Contact Us
Globální expert na kabely a kabelové systémy

About Nexans

Produkty a řešení

Služby zákazníkům

Pracovat pro Nexans

Novinky a tiskoviny

Jdi na

RHEYCORD®(RTS) (N)SHTOEU-J

Záložka Tisknout Kontaktovat nás
RHEYCORD®(RTS) (N)SHTOEU-J Extra Heavy Duty Reeling Cables
0.6/1 (1.2) kV
UL File ZMHX.E60412
In line with DIN VDE 0250 part 814
VDE Reg.-Nr.: 8185 / GOST R
Standart
Mezinárodní  Nexans specification
Popis

Applications



Extra heavy duty rubber reeling cable for control and power supplies. For applications with high mechanical stress, especially for simultaneous tensile and torsional stress. Suitable for motor-driven reels, spring-operated reels, drum spreader and hoisting systems.

 

Design


 

  1. Conductor
    Flexible stranded plain copper acc. DIN EN / IEC 60228 class 5
  2. Insulation
    Elastomeric rubber compound RHEYCLEAN-HEPR better than IEC 60502-1
  3. Inner sheath
    Special rubber compound 5GM3 acc. DIN VDE 0207 part 21
  4. Reinforcement
    Synthetic threads with very high tensile strength as a protection against twist stress and pressure loads
  5. Outer sheath
    Heavy duty chlorinated rubber compound 5GM5 acc. DIN VDE 0207 part 21; new special sandwich construction with incorporated braid for optimal flexibility and heavy duty application

     

Marking


Inkjet marking e.g.:
RHEYCORD(RTS) (N)SHTOEU-J 4x35 0.6/1 kV I NEXANS I year
VDE-Reg.Nr. 8185

 

Core identification


acc. DIN VDE 0293 part 308


 Nahoře
Vlastnosti
Konstrukční charakteristika
Type of conductor Flexible, Classe 5  
Material jádra Plain annealed copper  
Inner sheath Polychloroprene type 5GM3  
Sheath colour Yellow  
Outer sheath Chlorinated rubber compound type 5GM5  
Electrical characteristics
Rated Voltage Uo/U (Um) 0.6/1 kV  
Charakteristika použití
Samozhášivost IEC 60332-1-2  
Moisture resistance Yes  
Oil resistance EN 60811-2-1  
Ozone resistance Yes  
U.V resistance Yes  
Max. conductor temperature in service 90°C  
Short-circuit max. conductor temperature 250°C  
Ambient dynamic operating temperature, range -35 .. 80°C  
Ambient static operating temperature, range -50 .. 80°C  
RoHS conform Yes  

 Nahoře
Váš výběr
Construction type  
Minimum outer diameter  mm
Maximum outer diameter  mm
Approximate weight  kg/km
Použít
Obnovit
Výsledky   38/38
Výběr všech položek Nexans reference Construction type Minimum outer diameter (mm) Maximum outer diameter (mm) Approximate weight (kg/km)
79981307 7 x 1.5 15,0 17,0 315
79981312 12 x 1.5 18,0 21,0 447
79981002 25 x 2.5 + 5 x 1 CE 29,0 32,0 1300
79981305 5 x 1.5 13,5 15,5 260
79981405 5 x 2.5 17,5 19,5 450
79981407 7 x 2.5 17,5 19,5 450
79981412 12 x 2.5 20,0 23,0 620
79981418 18 x 2.5 24,0 27,0 871
79981318 18 x 1.5 21,0 24,0 606
79981324 24 x 1.5 25,0 28,0 854
Produkt na objednávku 7998.... 30 x 1.5 26,0 29,0 940
79981404 4 x 2.5 13,0 16,0 271
79981504 4 x 4 15,0 17,0 340
79981604 4 x 6 18,0 20,0 500
79981704 4 x 10 20,0 22,0 710
79981804 4 x 16 23,5 26,0 1060
79981854 4 x 25 29,0 31,0 1600
79986034 3x35+3x25/3 31,5 33,5 2030
79986050 3x50+3x25/3 33,0 36,0 2450
79986070 3x70+3x35/3 39,0 41,0 3450
Produkt na objednávku 79986055 3x95+3x50/3 43,0 46,0 4150
Produkt na objednávku 79986056 3x120+3x70/3 46,0 49,0 5150
79981001 19 x 2.5 + 5 x 1 CE 26,0 29,0 1090
Produkt na objednávku 79981304 4 x 1.5 12,0 15,0 200
79981430 30 x 2.5 29,0 32,0 1265
79981436 36 x 2.5 31,0 33,0 1525
Produkt na objednávku 79981444 44 x 2.5 35,0 38,0 1890
79981424 24 x 2.5 27,0 30,0 1165
79981444 44 x 2.5 35,0 38,0 1890
79981505 5 x 4 17,0 19,0 450
79981605 5 x 6 19,0 21,0 590
79981705 5 x 10 23,0 25,0 950
79981805 5 x 16 26,0 29,0 1270
Produkt na objednávku 79986057 3x150+3x70/3 53,0 56,0 6400
Produkt na objednávku 79986058 3x185+3x95/3 58,0 61,0 7800
Produkt na objednávku 79986227 3x240+3x120/3 67,0 69,0 10605
Produkt na objednávku 7998.... 6 x (2 x 0.5) C 22,0 24,0 790
79981003 6 x (2 x 1) C 26,0 28,0 815
Přidat do favoritů

 Nahoře
Electrical properties

 

Maximum operating voltage in AC systems
Maximum operating voltage in DC systems

Um
Vm

1.2 kV
1.8 kV

Test voltage (acc. DIN VDE 0250 part 814):
- Power
- Control


2.5 kV in AC
2.0 kV in AC

Current carrying capacity

acc. DIN VDE 0298-4
see PDF-File "Current-carrying capacities / Strombelastbarkeit"

Max. conductor resistance

acc. DIN EN / IEC 60228 class 5 - see PDF-File "Conductor / Leiter"

Reduction factors

see PDF-File "Correction factors / Umrechnungsfaktoren"


Mechanical properties

 

Bending radii

Outer-diameter of the flexible cable [mm]

up to 8

8 to 12

12 to 20

over 20

 -   fixed installation

3xD

3xD

4xD

4xD

 -   free movement

3xD

4xD

5xD

5xD

 -   Reeling application

5xD

5xD

5xD

6xD

 -   deflection pulleys

7.5xD

7.5xD

7.5xD

7.5xD

Tensile stress of the conductor

static
dynamic

15 N/mm²
30 N/mm²

Tests

alternating / reversed bending test,
roller bending test, torsional resistance test

Reeling speed

up to 240 m/min (higher speed upon request)


 Nahoře
Prodejní a dodací podmínky

Options

  • Further numbers of cores and cross-section upon request
  • Integrated BUS system cable
  • Integrated Optical Fiber Elements
  • Integrated pilot cores
  • Special flexible rubber compound for reeling application down to -45 °C

Související informace
RHEYCORD®(RTS) (N)SHTOEU-J   Conductors (66 kB)
RHEYCORD®(RTS) (N)SHTOEU-J   Current-carrying capacities (60 kB)
RHEYCORD®(RTS) (N)SHTOEU-J   Correction factors (56 kB)

Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map