RHEYFLAT®-N (N)GFLCGOEU-J

Záložka Tisknout Kontaktovat nás
RHEYFLAT®-N (N)GFLCGOEU-J Screened Rubber Flat Festoon Cables
Popis

Applications

Used for festoon and handling systems, machine tools, lifts and e-chain cable carrier systems. For applications with high mechanical stress and frequent bending in one plane only. Copper screens are efficient against electro magnetic disturbances caused by power cables (indoor and outdoor applications possible).
 

Design

  1. Conductor
    Flexible stranded plain copper acc. DIN EN / IEC 60228
    <= 25 mm²: extra flexible stranded, class 6
    >= 35 mm²: flexible stranded, class 5
  2. Insulation
    Elastomeric EPR rubber compound 3GI3 acc. DIN VDE 0207 part 20
  3. Screen
    Tinned copper wire braid, coverage > 80%
  4. Outer sheath
    Heavy duty chlorinated rubber compound 5GM3 acc. DIN VDE 0207 part 21

Marking

e.g.:
RHEYFLAT-N  (N)GFLCGOEU-J  12G1.5  I NEXANS I
 

Core identification

DIN VDE 0293 part 308 / HD 308 S2
4 cores: brown - green/yellow - grey - black
5 cores: blue - brown - green/yellow - black - grey
> 5 cores: black with white printed numbers - green/yellow - black


 Nahoře
Vlastnosti
Konstrukční charakteristika
Sheath colour Black  
Outer sheath Chlorinated rubber compound type 5GM3  
Electrical characteristics
Rated Voltage Uo/U (Um) 0.6/1 kV  
Mechanical characteristics
Cable flexibility Flexible  
Mechanical resistance to impacts Good  
Charakteristika použití
Electro magnetic interference resistance Yes  
Samozhášivost IEC 60332-1-2  
Moisture resistance Yes  
Oil resistance EN 60811-2-1  
Ozone resistance Yes  
U.V resistance Yes  
Max. conductor temperature in service 90°C  
Short-circuit max. conductor temperature 250°C  
Limit surface temperature fixed installed -40 .. 80°C  
Limit surface temperature, flexible application -30 .. 80°C  

 Nahoře
Electrical data

 

Maximum operating voltage in AC systems
Maximum operating voltage in DC systems

Um
Vm

0.7 / 1.2 kV 
0.9 / 1.8 kV

Test voltage  (acc. DIN VDE 0250 part 809)

2.0 kV in AC

Current carrying capacity

acc. DIN VDE 0298-4
see PDF-file "Current-carrying capacities / Strombelastbarkeit"

Conductor resistance

acc. DIN EN / IEC 60228
see PDF-file "Conductor resistance / Leiterwiderstände"


Mechanical properties FLAT
Bending radii according to DIN VDE 0298-3

 

Bending radii

Height of the flexible flat cable [mm]

up to 8

8 to 12

12 to 20

over 20

 -   fixed installation

3xD

3xD

4xD

4xD

 -   free movement

3xD

4xD

5xD

5xD

 -   Festoon application

3xD

4xD

5xD

5xD

Tensile stress of the conductor

static  / dynamic

15 N/mm² / 30 N/mm²

Tests

bending test

Festoon speed

up to 180 m/min, higher speed upon request


 Nahoře
Prodejní a dodací podmínky

Options

  • Special cold resistant compound
  • With integrated fiber optical element
  • Further options upon request

Související informace
RHEYFLAT®-N (N)GFLCGOEU-J   Conductors (66 kB)
RHEYFLAT®-N (N)GFLCGOEU-J   Current-carrying capacities (60 kB)